Answer Posted / karolson
Transformer bush failure causes include:
1:use of of improper conductor on termination
2:oveheating of transformer either due excessively load or failure of cooling system or internal fault.
3:loose connection on bush
4:oil spillage on bush
5:rust and moisture
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Proviiding the Dedicated N earth and individual Body Earths ,Finally these all looped /Now my Question :- will it not harm in case of Transformer Fault current flows in Dediacted N Earthing to Looped Body Earthing.
Does the motor power displayed on the Motor name plate is the mechnical power motor delivers or it is consumed power from the system?
what is the setting of locked rotor in HT motor ? (answer expecting in percentage)
Terminal blocks is used for segregate the connections... There is any principle for terminal block..?
During regenerative breaking= A rotating magnetic field is reversed B slip is positive C torque is positive D slip is negative
I'm looking for a mnaual set for a Teradyne J750. Softcopy would be preferred but I'll take what I can get.
What would cause a 240v choke that should give 110v out on a 16w lamp to gradually increase to 160v?
In control room of our one plant there is a continuously the incoming power goes to PC is vary,means in stabilizer it continuously indicate from high input to low and low input to high. what is the reason and its solution.
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
A 3 phase transformer's (Y-Y) Y and B phase is (Y and B connection not broken) broken from neutral and R and Nutral connection is ok, what will be the relay tripping and why
what are the things that can cause a three phase motor to crawl?
how r charge carriers produced
how much LT load can bear by the 100 KW HT connection.
If VFD is On but no starting commond on it. so how many outpout voltages of VFD
In all analog voltmeters or ammeter showing some small size symbols. as well as a star and in star 2no. digit, resister symbol,and other. what is that's meaning ?