To generate electricity , what is the speed of rotor?
Answer Posted / asdrfdg
A Synchronous machine can generate electricity even if the speed of the shaft is less than synchronous speed. But an induction machine starts generating only when its shaft is rotated with a speed greater than synchronous speed.
What makes the difference in these two types of machines, that one machine can generate electricity at any speed of shaft(but frequency of output power varies with the variation of speed of shaft), whereas the other one (induction machine) doesn't give any output power before a certain value of speed
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
how to calculate the size of the HT cable
Why we are using only Dyn11 tranformer in distribution system but not using a Dyn1 in distributing system?why not and advantage and disadvantage in both
Installation resistance for whole installation of 16 kva & 25 KVA DTRA a) Between each conductor b) between conductor to earth c) installation resistance for each apparatus, each conductor to earth d) earth resistance for the system of earthing
i have done diploma and btech in EE and live in Chandigarh so kindly help me how can i make my competency certificate in my area.
sir i completed apprentice in TNEB.apprentice is eligible for 'c' licence
How can I calculate per unit (KWH) fuel (Gas/ Diesel both) consumption 1MW unit?
What determines the thickness of the lamination or stamping?
i am gng to visa interview this july i have 4 backlogs gre 1010,toefl 75,pls give me the tips pls pls
Difference between megger test equipment and contact resistance meter test instruments?
delta motor winding resistance I take normally single winding is 2.5, which value is came delta connection ie RY ?
is ac supply can store
what happen when we add mentos in cold drink?& why?
Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?
True or false question. 1.The fuse provide phase and neutral 2.power loss in electrical circuit can take place in (resistance or inductance or capacitance). 3.two phase system each phase has separated by a phase difference of (90 or 180 or 270 or 45). 4.3 phase balanced star connected load neutral current shall be (line current or phase current or zero or unity)
Will any motor burn if voltage provided is lesser than the rated voltage???? If yes, then how is speed control possible with voltage control