if silica is removed from DM Plant completely from where the
silica come in Boiler Drum

Answer Posted / rao dv

The silica in ionic form (also reactive silica) is removed by strong base anion exchanger effectively. The traces coming out from DM PLANT and colloidal silica which is not removed by SBA EXCHANGER will be carried to the boiler drum. At the boiler operational pressures, the colloidal form will be converted to reactive form. Thus appears in boiler drum.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how can we find the discharge pressure of the pump with the use of flow and NPSH?

1393


Name the indicator diagram.

1874


I am Sunny..I have completed B.Tech(Mechanical).can i apply for Probationary Officer Post in Syndicate Bank 2010.Is that they hire engineers for PO Post?

1693


I have purchased some circlips @rs 100/- p pc on 01.01.2017 ans some @rs.120/- p pc/@rs.90/- p pc dt. 31.03.2017 what is the ending price of per pcs

948


what is 2062 stands for in is2062 material?

3286






What will cause if you run your engine in critical RPM continuously?

1816


Define weber number and its significance?

648


i am studying mechanical engineering third year.. i want to study ine year marine bridge coure.. is that good for me?

1457


What is add number

1008


what is pulverisation

18105


What is the gas constant r for air?

652


IN AC mechanical fuelpump what stands for AC? IN SU mechanical fuelpump what stands for su?

2836


What are the requirements of a good fuel?

1583


Explain the opening and closing of water to the bowl of the purifier

1778


define fans and explain its types?

1648