Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the components of a start and stop motor control?

Answer Posted / mohd azharuddin

It depends on type of starting methods u r opting, for example u can use DOL METHOD which requires one overload protection relay, one contactor, two push buttons, one nc and one no elements but the disadvantage of this method is high inrush current so this method shoudnt be used for big motors


Another method is STAR DELTA METHOD in which u require one overload protection, three contactors, one for main, second for star, third for delta, one timer with relay logic, two push buttons, one no and nc elements, in this method motor is started in star connection for the first few seconds and then changeover to delta, by using this method we can reduce high inrush current.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is meant by reactance voltage?

1147


WE know that for Inductor X=2pifL,In DC f=0,then X=0 so,V=IX=0;But In the DC excitation of rotor of AC generator,DC motor field coil which coils are inductor so why does not applying DC voltage short the rotor coil of AC generator and field coil of motor?If it would then DC source might be damaged but it is not happened. Why does the strand conductor of Electrical power transmission line make twist?

4387


Why is tan-delta test and capacitor measurement done on alternator?

2216


How to Calculate The Neutral Earth flat design calculation for the Synchronised generator (Gen 1-650Kva, Gen 2-725Kva

1655


In ht capacitor ckt we are using LBS Panel it having isolator with fuse, one of HT fuse flash over, so what is reason behind this event.

2090


What is the Current equation in series RLC circuits.

1055


How to calculate the sag on transmission Lines.

3014


what is the AC Plant and how can do the work with parts and picture tell us 150 Tr

2032


plz tell me,ht and lt panel terminals in substations explain beiefly

2931


what is the purpose of slope in the differential relay?why we are using two slope?but in busbar differential we are using only one slope.why?

2919


What are the no-load losses for the 11000/415V transformer with the following rated capacity? 1.1500 kVA 2. 2000 kVA 3. 2500 kVA 4. 3000 kVA

1759


Tell me in detail about c.t. And p.t. ?

1162


what is booster? and how it is connected in a circuit?

2625


Difference between drift current and diffusion current?

1884


In ups static switch if i gives the supply at output end it will open the circuit in stactic switch or not if it will open then how it operates.

2317