A distillation column separates 10000 kg / hr of a mixture containing equal mass of benzene and toluene. The product D recovered from the condenser at the top of the column contains 95 % benzene, and the bottom W from the column contains 96 % toluene. The vapor V entering the condenser from the top of the column is 8000 kg / hr. A portion of the product from the condenser is returned to the column as reflux R, and the rest is withdrawn as the final product D. Assume that V, R, and D are identical in composition since V is condensed completely. Find the ratio of the amount refluxed R to the product withdrawn D. Hint : Solve the simultaneous equations as follow in order to find the answer (R / D) : 10000 = D + W; 10000 (0.5) = D (0.95) + W (0.04); 8000 = R + D.

Answer Posted / kang chuen tat

Overall Process - Total Balance : 10000 = D + W. Benzene Balance : 10000(0.50) = D (0.95) + W (0.04). Solving simultaneously, D = 5050 kg / hr; W = 4950 kg / hr. Total balance around the separator : 8000 = R + D; R = 2950 kg / hr. Answer : Ratio R / D = (2950 / 5050) = 0.58. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.

Is This Answer Correct ?    15 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In a crusher where is the energy provided to it is used up for?

608


How can one estimate how the friction factor changes in heat exchanger tubes with a change in temperature?

563


I am a student of class 12. With PCMB group. But I Am not good at math. So I wanted to ask whether Chemical engineering can be a good option for me.???

1325


I HAVE DOMAIN KNOWLEDGE IN PROCESS MANUFACTURINGAND I GOT AN APPARTUNITY AS A BUSINESS ANALYST AND I DNT HAVE ANY KNOWLEDGE ON ORACLE APPS/GIVE ME ANY VALUBLE SUGGESTION?

1833


What is a good relation to use for calculating tube bundle diameter?

546






Explain what is a good way to get started in doing a plant-wide steam consumption analysis?

547


How can one quickly estimate the additional pressure drop to be introduced with more tube passes?

612


What is the ignition temp. of Aluminum,Coper&Iron.

1792


We are having proplem with the persperation smell in ETT/ECHO room in our cardiac hospital.The 2 Ton of AC is not conditioning the environment. We have to use exhaust fan to through out of the room bad air. Could anyone suggest how to coup with this effectively using chemical engineering. Any permanent solution to neutralise the bad smell.The Air freshners are not doing enough instead making a bad odour.

1727


Name some guidelines for designing for liquid and gas velocities in process plant piping?

567


Define an additive?

558


Why should chemical equation be balanced?

640


How can one determine if a particular solid can be fluidized as in a fluidized bed?

610


What is the maximum recommended velocity for steam in a plant pipe network?

708


How are vessel lined with glass or how are they coated?

624