Consider a case that two 200 hp motors are connected to 500KVA transformer. For improving power factor can we add capacitors in common bus bars to motors. Or should we add capacitors for each individual motor?

Answer Posted / manish panchal

Actually it depends on the motor's actual pf and the load with which motor is connected, so we have to connect capacitor with individual motor according to its pf.

Is This Answer Correct ?    4 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?

1215


Ratings of power transformer,Distribution transformer.

1095


the grid connection required for a 50 MegaWatt fotovoltaic powerplant is higher or lower than 35kv (high or medium tension)?

1432


what is ratio of copper wire size and current ?

1368


What is the height of DA, DAL, DB, DC & DDE tower?

1715






What are the various kind of cables used for transmission?

631


why normally Generator rating are between 11Kv to 22Kv?

3712


In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.

1128


How is efficiency of DG set calculated? At many places I found the efficiency to be mentioned in percentage. But at some other places I found kWH/ litres. I want to know how dimensionless percentage value is arrived at?

1406


from which formula we select a capacitor rating?

1621


what r substations?what r there work?why voltages r incresed and then reduced during distribution of power

1467


While performing stability test of differintial cts how to know the voltage and current on both side of the transformer?

3057


how to find out cable size if load is 2800 watts, 230 volts AC supply and load distance is 1800 meters

1091


What happens if we give the supply to the rotor of induction motor and make its terminal shorted?

3055


What happens if we connect a single phase energy meter in reverse polarity.

1715