What will happen if the Air Preheater is placed before the Economiser?

Answer Posted / dk

satuated temperature very low temperature and air heater outlrt air & pa air also hot air above 200c and fuel consumption not high as possible only reason for economiser o/l temperature only decreased

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525

1278


explain how the third harmonic content of the magnetising current affects transformer design

2773


How We Calibrate the vaccum transmitter?

1470


What is LB-SR.

2489


dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job

2072






DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

516


LAPT working in alternator / generator

2550


some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor

1950


our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....

1198


what is the meaning of SST300 V56A in SIEMENS turbine

3887


Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon

1769


What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?

1937


Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.

1882


We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?

1434


Why superheated are started before I'd and rd fan?

1693