If NO contact of relay gets supply from other sources or other part of circuit and at a time relay coil activates,then current will flow in which direction & will it cause to damage relay??

Answer Posted / rakesh

current will flow from no to common, and there will not any damage with relay coil.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how can maintaince the acb contactor moveing and fixing kit

1585


Hi,iam a diploma in electrical engineering.rtd from indian air force in apr 2007.prsently working in reliance next link as a network maintenance engineer since 2007,can i get a job in motherson sumi.

1894


Is there chopping current in resistive circuit

1534


What is different between resistance grounding system and resistance earthing system?

676


What is the previous name of Cox's Bazar

1455






why on axial hitting up of air blast on hydrogen produced in oil circuit breaker,temperature rises of the core of the arc?

1459


rajha power sector details

1536


Dear sir, my knowledge about cable size determination is limited. Though I read examples I could not calculate the Cable size required for electric driven pump 40 KW, 380 Volt, 50 HZ, 50 meter from transformer and it is three phase star delta starting. Please help as there is no one in my surroundings to help.

1285


If I want to connect a capacitor bank on the HT side of a 11kV/415V, 3 phase delta-star distribution transformer to supply Reactive power to it..what practical specifications of a Capacitor bank that can i've??please reply..

2036


i m electrical diploma holder i want to do plc $ Scada some body tell me which insitute is best for me near chandigarh

2649


How will A Medium voltage circuit breaker(11 kV voltage level) operate under short circuit fault condition whether It is having short circuit release like Low voltage circuit breaker or relay should be given?

1415


In our factory so many iron pillors are exists for supporting the shed/Hangar. If do more no of earthings at one piller instead of doing more earth pits in many locations and running earth strip around the hanger, I can save the money. Please suggest this method is acceptable as per Is specifications though the Earth resitance of the farthest piller is with in the limits as per IS specifications.

1645


What will happen if a dc source is given to a tubelight. Will it work or wont it work....

1484


Formulae for calculating the transmission line losses for different voltage levels

1616


hello friend i wish to study a course related to the electrical construction, controlling and monitoring , which course i want to study? pls give me the name of institute?

1333