what will happen, if both relay contact has live supply, and coil of relay activated

Answer Posted / kingshuk dey

I'm not sure what you mean by "both relay contacts have live supply". I mean, relay contacts ALWAYS have live supply.

Case 1: One side of contacts have live supply. When you give supply to relay coil, the contacts close/open (NO/NC logic), hence this "live supply" continues on to next part of the circuit.

No supply to relay coil: Live---[ ]---0 (NO contact)
Supply to relay coil given: Live---[/]---Live (NO to NC)

Case 2: Let's say the relay has only 1 set of contacts (SP), and both contacts have supply, then nothing will happen. It's like two live wires in a junction point.

Live supply 1 ----o---- Live supply 2
|____(lamp)--Neutral

Any supply switches on (or both) the lamp glows (the "o" point shares both supplies, think of it as mating relay contacts!)

However, if Live supply 1 and 2 are AC & DC, there's a shorted circuit.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is earthing transformer? draw the winding dia.of earthing transformer.

1239


how can get electrical "c" licence.i am complited in DEEE.PASSING YEAR OF 1993.WORKING IN PVT COCERN LT LINE.PLEASE ADVISE ME .CELL NO 9994786021

1521


difference between a diode and thyristor?

1767


how to increase senstivity of ct

1924


what will happen if there is a voltage leakage or current leakage in an electrical train

1503






how maney type tempereture measurement ?

1828


What is the suitable transmission voltage?

670


Q.1:What protection will be used on HT and LT side of 33/0.4 KV, MVA transformer. Indicate capacities of protective device to be used. Q.2:Which types of back-up protections are used in the power transformers? What do you understand by the term over travel in the relay? Q.3:How star and delta connected winding transformer are provided from earth fault

1697


Explain what is use of lockout relay in ht voltage?

674


A 1F capacitor is charged to 100V initially. A 1H inductor is connected accros the capacitor througha a switch. The current in the circiut when the switch is closed is____

1868


Explain cos(theta) and Sin(theta)

1628


IN MY SYSTEM THERE IS ONLY OVER CURRENT EARTH FAULT RELAY IS AVAILABLE. FOR THE UNBALANCE SENSING IS THERE ANY RELAY IS AVAILABLE? THE SAME CTs WHICH ARE USED FOR THE OVER CURRENT EARTH FAULT RELAY CAN USE FOR UNBALANCE ALSO?

3192


What is a single phase autotransformer?

633


If any one's require of phoenix contact like( relay , termilnal block , surge protection device ) , product please contect me 09878206357 chetan verma

1637


Two bulbs of 100w and 40w respectively connected in series across a 230v supply which bulb will glow bright and why?

620