Can we see the poles in the motor?. if yes then how can we see plz tel me

Answer Posted / deshraj bairwa

Yes by applying flemmings thumb rule

Is This Answer Correct ?    6 Yes 13 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1. for eg, capacitor is used for many purposes(it act as filter, oscillator, bypass capacitor, memory storage etc...) 2. Please tell me some example circuits for different uses of capacitor( whenever and whereever and however we used capacitor as a filter, oscillator tuning etc..) 3. similarly for inductor and resistors(it act as what?) and when and how we want to act as like that?, and how we can used these components depends upon our requirments with example circuits and explanation? design to act as these components depends

1377


My question is abt backlog.I had dropped one subject in my second year, and completed this subject in the 3rd attempt, so how many backlogs i have got?1 or 3?plz sujjest the answer as soon as possible

1597


can any one tell in easy method for circulating current ??

1654


what are the basic insulation levels & what its Unit

1500


I have a situation to design sub-Distribution board/Panel meant for feeding power sockets. In the incomer CAN i Take TP MCCB with Neutral Link and All the outgoing feeders with to sockets with TP MCCB and Neutral Link? P.S : My System is IT Earthing

1323






In convertor can we use rectifier thyristor in place of invertor thyristor with explain.

1384


Why can't we parallel Voltage transformer secondary circuits?

973


can we find the inductance of a induction motor?

1559


how can found motors folt current ? how can disided circuit breakers caoicity and breaking capicity ?

1626


If we connect a motor and generator together (I mean that the generator gives the motor electricity and the motor gives the generator movement) regardless the losses. Will the generator still generate and the motor still move?

1710


how to revers the direction of single phase motor

480


What kind of maintenance is conducted for Transformer

1745


HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.

1462


what is the main difference between power devices and signal devices

1701


list of tests to be carried out at manufacturers end while purchasing a step up transformer of 11kv to 66kv ,2MVa Capacity.

1562