Answer Posted / dipen patel
Genrrally its depends on manufacturer. also brown colour are easily visualable.In a india mostly brown are use but in a many country blue and white also used .not a actual reason for a brown .@@@@@Dipen patel.@@@electrical department @@@gutarat tec. uni.
Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
A 10 MVA, 66KV, 50Hz, Y-connected 3-phase alternator has synchronous reactance of 0.635 Ù. It is working at full load at 0.8 lagging p.f. condition. Find torque angle, neglect armature resistance.
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
what is power factor ? how we can calculate the low power factor and amount of capacitor for improve that low factor ?
I am having a 1500 KVA transformer whose secondary current is 2086A and my connected load is 1000 KVA, I am having 400 KVAR APFCR for PF improvement what ratio of CT should i install in LT EB Bus to get optimum PF improvement?
please describe the Transformer setting, Motor setting, I/C setting, Tie setting
draw the restricted earth fault protection circuit install on power transformer and identify its parameters and draw C/C curve of it
Dear sir, I have completed DECE in the year 1995. I have work experience in HT and LT LINE more than five years. Now i am doing BE in EEE from rajasthan university. After completion of BE,can i apply "C" Licence sir? Please reply.
What range of speed can you get with the armature control method of speed control of d.c. Shunt motor?
what is current check gurd relay?
Whether 3 phase induction motorwith 100 hp capacity , Amp 160 for which sensitive earth fault relay , type CTUM 15 can be used?
Which contains in POLE ASSEMBLY of a 11KV Kirloskar-make SF6 (Model No-FP620A12)? Will u clarify with drawing?
which book to refer in electrical engineering for iocl exam & which book for general english.
Show the schematic arrangement of diesel power station layout and give its principle of operation.
How a band pass filter is constructed?
what heppend if we are connected u1-v1-w1 as a star point in the place of u2-v2-w2 in power genration