Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between AMF panel and DG
Synchronization panel? please define the working of both
the panels?

Answer Posted / bhupinder singh verma

  AMF Panel: is Auto Mains failure panel. When the EB power goes off with a time delay signal will go to DG self 
starter to start the DG. And when the EB power 
resumes,after definite time delay stop signal goes to DG 
and EB supply contactor will become ON.For a fraction of 
time power will not be there for the utilities.



In synchronization OF DG SETS, When the EB power goes off with a time delay signal will go to DG self starter to start the DG AND WHEN THE LOAD REACH THE 90% CAPACITY OF THE DG-1 THEN THE DG-2 WILL START AND THE DG-2 gen-set is to synchronize with the existing DG-1 THEN ,we've to match the magnitude of the voltage, phase angle and the frequency and then only we've to switch on the incoming set's breaker. THATS WHY THE OUT PUT SUPPLY SUPPLY OF BOTH DG SET WILL RUN ON THE SAME COMMON BUS BARS ( MEANS- DG-5OO KVA / DG-2 380 KVA THEN THE TOTAL LOAD IS 780 KVA ON COMMON BUS BARS ) IN THIS WAY WE CAN SYN. ELECTRICAL CITY BOARD POWER AND DG POWER ALSO.  

Is This Answer Correct ?    8 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is size 00, 01, 1 etc., in HRC fuse types?

2389


PLEASE INFORM ABOUT THE IDEAL TEST RESULTS OF MAGNETIC BALANCE TEST OF TRANSFORMER 33/11 kv DELTA-STAR T/F

2219


WTA used cb?

1943


What is earth?

2451


why tertiary winding is used in transformer with diagram?

2260


what is charger supervision and control supervision?

2079


After doubling voltage from solar cells & use step down voltage transformer can we get high current output with low voltage.

1991


how to calculate earth fault relay current and CBCT ratio

8354


What is the maximum and minimum rating of UPS?

1540


How to calculate capacitor bank size at a load 800kVA.

1723


Why Neutral Isolation is required?

2241


What is acsr cable and where we use it?

1170


8. A DYNAMOMETER TYPE WATTMETER RESPONDS TO THE.......

9303


How many double suspension hardware fittings are required on a double circuit transmission tower?

1937


Is there any relevant technique to produce power from light and heat energy of the sun simultaneosly from same rays of light?

1886