what is the difference between the microcontroller and PLC?
Answer Posted / waseem
microcontroller cannot be used at large scale so plc is used.
( 2)ladder language is quite simple
(3)plc can be easily reprogrammed than microcontroller
| Is This Answer Correct ? | 3 Yes | 2 No |
Post New Answer View All Answers
need to calculate flow rate with the help of dp range and orifice bore dia and size. range is 0 to 400 inwc and orifice size is 12 inch 150 # rf and bore dia is 7.180 inch. need to calculation for flow rate
any one can send me instrumentation previous interview papers? I prepare for MNC Company Interviews? my mail id- Rakesh.Golla@dodsaldxb.ae , and another mail rakesh.gvk@gmail.com
Which is the best field foundation bus. ( FF ) Yokogawa, Honeywell or others ?
What are the uses of orifice plates?
in sulfur process what is material of impulse line we use to connect with transmitter ? and does teflon affected by sulfur?
What is the minimum rating availalbe for weld neck orifice in market?
how to calculate orifice sizing? and tell me if pipe size bet 50mm t0 200mm then we can use pipe flange??? and above 250mm pipe size should i use D & D/2 Flange? is it right or wrong?
What is limitation of the ht.of the displacer of a level trol?
Explain PID, ON/OFF, Controls
Draw a group of instruments interlocked to a Pump & Motor?
what is the reason while warning lamp is on while the engine is cranking?
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
In my company plc based winders are operated. one day there was a data transmission failure alarm shown on pc. as per sir instruction we have reset master plc but winders were not triped and alarm gone. so what master plc do?
How do you identify between actual alarm and false alarm in a Temperature Transmitter in SCADA based Control System
we have a s-5 simense plc having op7 .recently on op7 showing error 1.plc not present 2. DB error frequently. can u have any solution . please send me.