What is mean by SMART in an Instrumentation. is any full form
for SMART?

Answer Posted / gireesh mohan

SMART - Self Monitoring Analyzer And Reporting Technology
SMART - Single Module And Addressable Remote Transducer
SMART - Single Module Auto Range Transmitter

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?

1737


i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1001


What is the diffrence between digital signal processing and discrete signal processing?

1591


can you provide me full detail about instrumentation in ONGC??

1762


what is controlling card in dcs? how u measure dcs memory?what is bus in dcs?how u know dcs speed n ehternet speed?

1515






Meaning of the following a. IOP- Manimum; b. IOP- Maximu,;

1665


what is the PC interface and software for connection to ABB logic module “ LM011-CE18RAC “ ( for Programming ) ??

3443


what is IEC code in cables & how to selecting cables?

1296


Why we are using DPT(Differential Pressure Transmitter) in separator instead of level trasmitter?

1781


What are different types of control valves?

702


Why does a pressure gauge installed on reactor, doesn't have any vent line below to release the pressure? Is it any kind of designing mistake or it actually does not require any vent line? And if it does not require any vent line below it then how we are gonna release the pressure built inside the pressure gauge?

1723


i want formula for flow control.am doing project in flow control using orifice . i know value of the flow level(Q) . upstream(p1) pressure, orifice diameter(Do) , pipe diameter(Di) and oil viscosity(Vi) how can i calculate downstream pressure

1454


What are primary elements of measuring pressure?

768


How to calibrate capillary type level transmitter

1206


A valve in series with an orifice plate (DP transmitter), is aligned for constant pressure in the pipeline, if there is an error dx, How to align it in process.

877