there are two candidates p and q in an election.During the
campaign,40% of the voters promised to vote for P ,and rest
for Q.however, on the day of election 15% of the voter went
back on their promise to vote for P and instead voted for Q.
25% of the voters went back on their promise to vote for Q
and instead voted for P.suppose,P lost by two votes,then
what was the total no. of voters.
Answer Posted / javed
20
| Is This Answer Correct ? | 2 Yes | 8 No |
Post New Answer View All Answers
How to change dcs card in online. (Dsc is maxdna)
What is hp & mp seperator .& what is its working principle ?
Why rdt and thermocouple both give different output .and one things more, how to generate ohm or mili volt plz mail me merajalam143545@yahoo.com
Hi i m B.E. In elect. & comm. I m workin in bio mass plant from 6 mnths as inst. Engg. but now i m in dept. Of operation as shift engg...which is best operation or inst. 4 me? M confusd..plz help and reply me..
What is three element in drum level?
What are different types of orifice plates? State their uses.
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
whatis range of marcury filled tempereture gague
how to calibrate corollaries (Mass flow meter)?
In turbine what does term CDP, NI, NH, HSSOC means.
What is the use of temperature compensation?
i am from instrument branch i want paper patern of mahagenco . any pevious years paper regarding my branch send me please . please.....
Explain the working principle of lvdt?
we are having yokogawa centum cs3000 dcs in our power plant. i need some of the operator guides NOT to appear in HIS0163 AND HIS 0162 but it shoul appear in HIS0164 HOW TO DO IT?
Drum level tx with GP4 with zero elevation:7300mmh20 on HP and 8050mmh2o on LP as range but on commissioning the tx readiing is max,Why this reading?