How damper winding in synchronous motor suppress Hunting?

Answer Posted / nidhi sharma

When a synchronous motor is used for driving a varying load, then a condition known as hunting may occur. Hunting may also be caused if supply frequency is pulsating (as in the case of generators driven by reciprocating internal combustion engines).

We know that when a synchronous motor is loaded (such as punch presses, shears, compressors and pumps etc.), its rotor falls back in phase by the coupling angle \alpha. As load is progressively increased, this angle also increases so as to produce more torque for coping with the increased load. If now, there is sudden decrease in the load, the motor is immediately pulled up or advanced to a new value of \alpha corresponding to the new load. But in this process, the rotor overshoots and hence hence is again pulled back. In this way, the rotor starts oscillating (like pendulum) about its new position of equilibrium corresponding to the new load. If the time period of these oscillations happens to be equal to the natural time period of the machine, then mechanical resonance is set up. The amplitude of these oscillations is built up to a large value and may eventually become so great as to throw the machine out of synchronization. To stop the build up of these oscillations, dampers or damping grids are employed. These dampers consists of short circuited Copper bars embedded in the faces of the field poles of the motor. The oscillatory motion of the rotor sets up eddy currents in the dampers which flow in such a way as to suppress these oscillations.

But it should be clearly understood that dampers do not completely prevent hunting because their operation depends upon the presence of some oscillatory motion. However, they serve the additional purpose of making the synchronous motor self-starting.

Is This Answer Correct ?    7 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how much cable size required for 70 kilowatt load.

1152


Dear All, I am new in construction company , my boss ask a question at time of interview , If we have 60MW generation and Single Power Transformer step-up we have. if CMR 50/60MVA , ONAN, ONAF respectively , is it sufficient or not ? for that much power to transfer,

1220


USE OF 8 WAY PAN ASSEMBLY

1497


What is slope...? Explain slope 1 and slope 2...?

1082


A 230V dc shunt wound motor has an armature resistance of 0,15Ω.When operating on no load at 650 rev/min the armature current is 6A . The motor takes a full load current of 85A. Calculate the full load speed if the field flux is (i) maintained constant (ii)reduced by 0,03

1599






how to select the double earth conductor if 21A full load?

1564


What is superposition theorem?

706


hi this is hema can anyone mail me previous years questions for the APPSC-A.E.E (in electrical stream.) ......thank u.

1465


what are inductive and capacitive voltage transformers.what are their applications

1505


How seriving & testing of the HT & LT breakers are done. What are the standard Ir values on which we can come to know the test is passed or failed?

1520


What is instrumental error?

691


how to get bearing & winding temperature of an induction motor?

1464


how can i reduce sparking without stepdowning the voltage

2085


What are the insulation standerds for eg H clase and how many insulation standerds are there and its standerds??????

1491


How to Calculate KA Rating of Main LT Panel

1184