Answer Posted / nirmal
It functions by having two parallel tubes both containing
gas and heating coils. The gases are examined by comparing
the rate of loss of heat from the heating coils into the
gas. The coils are arranged in a bridge circuit so that
resistance changes due to unequal cooling can be measured.
One channel normally holds a reference gas and the mixture
to be tested is passed through the other channel
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
PT RTD Range: -200 to 500 degree celsius If I configured in DCS Lower range and Upper range . In face plate it shows red colour due to overa range how was the characteristics look If the temperature is more than operating range. how was the characteristics look . whether its in Resistance vs Temperature curve is Linear or Non linear
i need some objective type questions in instrumentation
what is the procedure to callibrate temp controller ,pressure controller,etc. suppose a temp controller showing error 1.5 degree centigrate how can i minimize it.
What is critcal speed. what is resonant frequency. why we want to cross crtcal speed on higher RPM (early).
How many are the types of instrument cables in terms of No. of pair.
hi i am eswar i want to know the instrumentation interview questations for eil(engineers india ltd) i have applied for engineer post in eil please help in this.my mail id eswar310@gmail.com
please tel me the calibration of pneumatic controler.
please send the sample qustion paper for iocl written test ..
can we copy the software from a transmitter using hht(hart 275) ?
I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?
Punj lloyd is coming in our Jadavpur Universtiy campus for campus placement. Please send me some hints about the writtend exam. My email id is subratafriends@gmail.com
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
field bus transmitter calibration procedure tell me
What is Positive Calibration and Negative Calibration?
what is easiest way to read STL language in PLC?