Possible cause of IOP alarm in a DP transmitter:
a: IOP-minimum
b: IOP-Maximum
Answer Posted / dass
IOP is an alarm condition where in the input data has become a bad value as a result of disconnection of a detection terminal or process I/O device or the abnormalities of input destination data .
| Is This Answer Correct ? | 19 Yes | 1 No |
Post New Answer View All Answers
what are the steps I have to deal with?
Explain the working of an electronic level troll.
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
how to calibrate and troubleshooting of leveltroll?
How to Calibrate Ultrasonic flow Transmitter in Field
why we us isolation barrier in hazardous area how it works to protect the area and please clarify its current flow.
Drum level tx with GP4 with zero elevation:7300mmh20 on HP and 8050mmh2o on LP as range but on commissioning the tx readiing is max,Why this reading?
How to Calibrate Level Troll in field
Draw bode plot of any transfer function. Why is plotting bode necessary?
How can i test procedure grounding for CAT-7 cable? Or How can we test procedure CAT-7 Cable Electrically safe?
What is PDS and PDMS ?
What is feed factor and its Importance in cement industry? How we can solve feed factor?.
How can a d.p. Transmitter be calibrated?
I will attend an interview with GasGas company for a position of Instrument Technician ( Offshore )in next month can anyone tell me what questions they will ask. Thanks in advance.