Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between sdv and bdv ?

Answer Posted / krishnakamesh @ j.e.

sdv means shutdown valve
bdv means blow down valve
Both are used in ESD (emergency shutdown) condition.

SDV: ( closed valve)
it was used in plant inlet & outlet places.whenever plant
was partially OR total shutdown condition, at that time
plant was not disturbed from/to another process,closed the
disturbed process through SDV".

BDV : (opened valve)
It was used in sudden flare OR pressurized
condition,relief that pressure( to avoid dangerous
condition) used this valve.

Both are operated with solenoid valve, with electrical supply.

any thing want more refer google

Is This Answer Correct ?    18 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to calibrate corollaries (Mass flow meter)?

2184


how can we tune a PID. If it is by zeiger nichols method..please explain briefly with help of an example.

2492


What is the GK Value in Flowmeter?

3712


Explain why plc require in analog input 4-20amp & 0-10 volt?

1105


Explain the difference between plc and cnc?

1086


For what reason would you possibly be compelled to make use of a Smith Predictor. Explain the idea behind the operation of this device.

1937


How process line mpm calculation is done?

1430


How will you calibrate an Absolute Pr.Transmitter of range 400mmHg absolute ?

2045


Define cryogenic?

1183


What is limitation of the ht.of the displacer of a level trol?

2404


Why do we floating DC in DC system.

2909


Which Signal hart communicator work? If there any signal change when hart connect while transmitter in line ?

1419


How to Calibrate Radar Level Transmitter in Field

1260


how to calculate orifice sizing? and tell me if pipe size bet 50mm t0 200mm then we can use pipe flange??? and above 250mm pipe size should i use D & D/2 Flange? is it right or wrong?

1892


What care will you take in the installation of control valves,SCADA,DCS and FOC in Oil and Gas Project?

2141