howmany insolaters needed in 66kv line

Answer Posted / rakesh shandilya

There are four in suspension and five in strain for 66 kv line.

Is This Answer Correct ?    22 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why can't we parallel Voltage transformer secondary circuits?

973


FOR 16/20 MVA 132/33 KV ONAN/ONAF TYPE TRANSFORMER IT IS DESIGNED FOR 16 MVA WITH ONAN CONDITION.IT BECOMES 20 MVA UNDER ONAF CONDITION.LOAD LOSS IS GUARANTEED FOR 65KW AT 20 MVA AND % IMPEDANCE 13.75. PLEASE TELL US AT WHAT LOAD LOSS AND % IMPEDANCE IT SHOULD BE DESIGNED FOR 16 MVA AND WHAT WILL BE ITS EFFICIENCY AT 20 MVA?

2952


what is earth pit , how we can measured it, what earth rods reference

2070


how to test reverse power trip?

3885


In a synchronous motor. if start is running at high speed.  What will be the starting torque : Higher Lower Zero

1255






he compression ratio for a petrol engine generally lies between

708


Hi everyone, I'm Lachuu, recently joined automation company as PLC Engineer. I have certain basic question, I request all big gurus and seniors to answer these question. Because this will be very helpful to me as well starters like me. How to design a control circuit (ex: pick & place - my current project) Yamaha robot PxYx series controller RCX222, using 6 cylinder double acting, plc keyence kv p16r 2 expansion unit for input and output each. How to select panel terminal mcb elcb powersupply. My main concern in some projects how to select dc power supply, mcb rcb(I came across dif bt b c d curves, but stil confusing, pls help me :-(. I would really appreciate all who are going respond to this question.

1508


I am EEE student i want to improve my core side skills.how cn i approach it?

1990


How much current will a 5 HP delta connected motor at no load will take?Is tat need a starter

6710


Calculate torque developed by the 3-phase, 5 H.P., 4 pole induction motor runs at 1500 rpm A 23 N-m B 21 N-m C 10 N-m D 0 N-m

4357


What is open loop and control loop systems?

696


Hi everyone. Some Generators uses 3-Pole breakers with extra contactors for Neutral. Some uses 4-Pole. Why so? What is the idea behind this? Thanks in advance for the solution. Kr.

1618


how many types of motor can be used in washing machine

1685


why can the rotor of 3 phase slip ring induction motor not be a 2 phase rotor?

1564


when generator short circuit condition, the current how dissipates. or at short circuit voltage not available then current how can flow?

1758