why we require Differential pressure?Why we use Orifice Plate?

Answer Posted / anant shinde

In order to measure the flow rate through a pipe we require the DIFFERENTIAL PRESSURE because Flow Rate is directional to the differential pressure.

Orifice is a flow meter which produces a differential pressure across itself and measures the flow rate using U-Tube manometer.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?

5230


How to decrease opening & closing time of on/off valve?

972


centrifugal compressor interlock? Tell me the parameter at which compressor will trip

2691


Name different parts of a pressure gauge. Explain the use of hair spring in the pressure gauge.

672


Actual using of tube bender to bend 2 opposite 90 deg at correct measurement center to center of tubing.

1500






What is 3 selection available when configure the burnout protection for controller

2075


what happen if i increase height of displacer type LT.accuracy or sensitivity are affected.why?

2075


what is intrinscily safe system and where we use?

2005


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device ( from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

1639


we have a s-5 simense plc having op7 .recently on op7 showing error 1.plc not present 2. DB error frequently. can u have any solution . please send me.

2160


how pressurize drum calibrated ?

1578


What is the use of gauge?

695


What is instrumentation control?

653


What is the working principle of the magnetic meter?

631


how to calibrate electro pneumatic positioner 8013 mil controls ltd ?gsr

7454