Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the sensor types of vibration&speed?n what is
proximity sensor?

Answer Posted / manoj

Vibration sensor based on 1)fixed pt sendor 2)variable sensor
fixed sensor -by manual scale fixed near to machine
valiable sensor-1)seismic transdusar 2)clectromechanical
tranducer 3)capacitive rtnasdusor 4)proximity type
5)photodiode type
proximity type -it is eddy current type .when we are giving
supply -24 v.sensor develop Rf field.in machine eddy current
develop ,due to current loss of power in Rf field so we get
in o/t less voltage depend on gap voltage

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the difference between Cv and air consumption? why the customer needs Air consumption details?

1989


How an rtd work, and what volts/current goes to a rtd to measure the resistance?

1286


Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72

2221


what effects a surging can produce in the compressor

1930


principle of dead weight tester ?

2076


What is rang ability?

2347


Im having problems with interfase betwen SPI v7.0 and SPPID v5.05. Previous versions of Intools shoul be fixed with SPPIDproj.ocx file. It was necessary to replace this file with one that allows the connection between different versions of SPPID. It is necessary in the current version to do the same?Thanks

2316


what is the protection system in solar turbine compressor

2202


Pressure tx shows 1 mbar but we need 1000 mbar at this process condition .. how can we sort it out .

1708


If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?

1468


define feed forward control loop with example and drawing?

3215


Explain the key components of control loop?

1072


what is different between 2,3&4 wire rtd and how much maximum distance using plc to field.

2786


What are advantages and disadvantage of the ac supply load cell?

1065


Why boiler chimney area  oxyden sensor fixing? 

2496