1. what is 3 point calibration & 5 point calibration?
2. If we use hart communicator to set the LRV & URV of a
smart transmitter, did we calibrate the transmitter? why?
3. Make a complet list if meterials needed to properly
connect a pressure gauge to a steam pipe using 1/2 inch
stainless steel tubing. The gauge connections is 1/2 inch
NPT-M and the steam pipe tap has a 1/2 inch female coupling,
compression fittings are use.
4. What are the tools in loop checking?
5. What would the ISA symbol of a square root extractor look
like?
6. What would you do to completely prepare for the
configuration?
7. What safety measures must you undertake when doing
configuration?
8. what are the two most commonly use programming languages
used when we configure a PLC?
9. What would you do if you accidentally skipped a step in
the configuration procedure?
10. How would you know if the configuration were sucessful?
11. Name at least 3 selections available when we configure
the burnout protection of a controller?
Answer Posted / anand.r biocon limited
1. 3 & 5 point calibration
When calibrating the field instruments or device under test only 3 process reading compared with master instrument for 5 point calibration you should do comparison for 5 process values with master instrument
2. If we use hart communicator to set the LRV & URV of a
smart transmitter, did we calibrate the transmitter? why?
This is not calibration of transmitter we can say this is configuring BASIC parameters to the TX.
3. Make a complet list if meterials needed to properly
connect a pressure gauge to a steam pipe using 1/2 inch
stainless steel tubing. The gauge connections is 1/2 inch
NPT-M and the steam pipe tap has a 1/2 inch female coupling,
compression fittings are use.
By using sypon and 1/2 " nipple you can mount the pressure gauge on steam line if the line is vertical you should have 45 deg angle to the process line to reduce the pressure drop across the instrument.
8.. what are the two most commonly use programming languages
used when we configure a PLC?
Ladder logic
FBD- Functional block diagram
| Is This Answer Correct ? | 14 Yes | 0 No |
Post New Answer View All Answers
how can we tune a PID. If it is by zeiger nichols method..please explain briefly with help of an example.
Q- Control problem are mainly classified in _____ types. a-)4 b-)3 c-)6 d-)nono of these Few of them i know is 1- regulator type problem (eg- Air conditioner) 2- tracking problem (eg missile trcking problem) 3- sybernatics 4- optimal control problem
What are de-saturators?
the whole paper was based on Transducers..questions like define repeatability, error,accuracy,precision..den there were many q. on the conversion of Pa to mmHg and other units.. also..der wer few Q. on some level sensors(with diagram)
Why 4-20 amps is being used in instruments? Why cant we use any other range instead of 4-20 amps? Why only 4 amps is taken as lower limit and why 20 amps is taken as the higher limit?
what can of fault ofently come in vibration mesurement?
what is the criteria to decide conductor size of a cable ?
what is The specifications for oriface instalation
how to calculate orifice sizing? and tell me if pipe size bet 50mm t0 200mm then we can use pipe flange??? and above 250mm pipe size should i use D & D/2 Flange? is it right or wrong?
how to calibrate corollaries (Mass flow meter)?
PT RTD Range: -200 to 500 degree celsius If I configured in DCS Lower range and Upper range . In face plate it shows red colour due to overa range how was the characteristics look If the temperature is more than operating range. how was the characteristics look . whether its in Resistance vs Temperature curve is Linear or Non linear
i am having information technology branh ....... can i prepare for psu exam
Why boiler chimney area oxyden sensor fixing?
what is SIL 1 2 3
what are the different types of Protocols? & their applications.