What is the difference between Analytical instruments and
other instruments?

Answer Posted / akash karmakar

The measurement of composition is usually refferd to as analysis and the corresponding system as analytical instrumentation. the instruments which are used for any kind of analysis purpose.......

Is This Answer Correct ?    2 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Hi Friends i am going to write BARC written test by this month 20th (20-5-2008). So please if any body knows the details about this or having previous question papers pls mail me to kkumarei@gmail.com. For Suggestions give one message to 9962122264

1984


Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72

1652


wich is coming the first HAZOP OR SIL

2313


Which products are available in the Mass Systemswitch and System Manager AC range?

1496


How to calculate P,I&D value in PID controller ?

1625






Draw bode plot of any transfer function. Why is plotting bode necessary?

1871


-/5A. What is the meaning and limitations of this in energy meter constant. It is a 3 phase LT Energy Meter. If this Energy Meter is connected through a CT of ratio 200/5 Amps, then what is the multiplying constant and how its will be calculated.

1926


can u plz send me technical questions asked in SCHNEIDER ELECTRICAL technical paper?

4287


how can we tune a PID. If it is by zeiger nichols method..please explain briefly with help of an example.

2016


What is instrumentation control?

652


the pump holds on run indication into the dcs and filed local control panel remote push button condition operaton wrong like when the push button pushing conditions the pump is off and the push button release condition the pump is on totally opposite condition . And control room inside give the stop command into dcs just 1secon relay engage and again normal condition. How can I slove

1134


applications of plc in printing and packaging?

1682


what is the current pay package for an instrumentation engineer having 2 years of experience in cryogenic technology???????

4276


what step is taken for ESD ( emergency shut down) in DCS REPLY to hashimka20009@gmail.com

1890


selection criteria of control valve? and selection criteria of actuator explain in brief?

3655