In a Synchronous generator, Can AC voltage be used instead
of DC voltage in field winding of rotor to produce AC power?

Answer Posted / nitin nawaghare

IF YOU apply AC source then it will act as a transformer and
work on mutual inductance like transformer. if you rotate
its rotor then it generate the power with higher frequency
(Harmonic.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to calculate energy stored in an inductance?

649


state the disadvantages of carbon filament???

2372


Where is servomechanism used?

663


A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram

2380


Hi.. I am a BE GRaduate in E&E. I have 8.5 Experience in Tendering & Estimation field. I have done SAP SD course few years back. But due to some reason i failed to get job in that field and continued my own field. Now I am thinking of changing into SAP seriously. How should i go ahead???

1475






What is the limitation of kirchoffs law?

652


how to design the heater in temperature control unit to heat 50KL of water?

1432


How to calibrate or test an LT Air Circuit breaker 440 volts, 35 KA, 800 Amps ?

2121


what's the difference between 'shaft power demand' and 'BHP' , when we consider electrical load list.

1089


Explain about Dubai electrical sysaem? Explain about Dubai drinking water system? Explain about Dubai Burj tallest building Electrical,Water.etc.. maintenance system?

1662


When we have earthing mesh or underground earthing network in industrial plants, weather we have NT-S or NT-C-S kind of earthing system, so eventually weather we must use 4 or 5 wire in 400 volt level (For example 3×150+70 mm2 or 5×150 mm2) in this connection I would like to know exactly the paragraph of IEC or IEEE number

1699


Atwhat condition reverse power relay will act?

1804


dc supply given to dc generator winding.how is possible? my knowledge is saying the winding will burn. please reply.

977


which types of relay used in acb and vcb?

2318


What will be advantage if we put some load in neutral of grounded star transformer & loadshortcircuit current,rated current of cable & MCB with example?

1418