If single phase voltage level is 230V than why three phase
voltage level is not 660V ?, but it is only 440V.
Answer Posted / m.ubaidullah khan
In three phase power line, each phase is 120 degree from the other phase.therefore, when we draw a graph of phases then two phases have positive values then at the same time the third one has negative value so we can calculate and use only two phases at a time.all three phases changes their position every time so the two phase may be phases 1 &2/phases 1&3 or phases 2&3 gives the values and at the same times phase 3 or 2 or 1 will be at negative interval respectively so cannot be calculated or contribute the value. that's the reason we use 440v instead of 660v.
Is This Answer Correct ? | 34 Yes | 3 No |
Post New Answer View All Answers
How do you calculate the actual power consumption of an inductive load appliance. Say, a deep freezer of 200watts
in wind mill use 2100 kw asychronous generator ( induction generator ) rotor voltage : 3300,stator voltage : 690, rpm : 1511 type : MRL063E04 ' we check rotor resistance magger value found following. R-EARTH - 00 M.OHM,Y-EARTH-34 M.OHM,B-EARTH- 33M.OHM R-Y: 31 M.OHM, Y-B: 00 M.OHM,B-R :33 M.OHM HOW CAN I TAKE DECISION?pls ans. quickly
On Which Pressure PRV is operated.
what is diff btw electric,magnetic & eletromagnetic field
Difference between On Line capacitor and Station Type capacitor.
I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?
CPC cable .PVC \1C....I want to get sure that type is flexible indoor or to be install on trench. please advice .thanx :)
what is mean by PIR in circuitbreaker and give me detail of that?
IN MY SYSTEM THERE IS ONLY OVER CURRENT EARTH FAULT RELAY IS AVAILABLE. FOR THE UNBALANCE SENSING IS THERE ANY RELAY IS AVAILABLE? THE SAME CTs WHICH ARE USED FOR THE OVER CURRENT EARTH FAULT RELAY CAN USE FOR UNBALANCE ALSO?
draw vector diagram and +ve,zero sequence diagram of symmetrical three phase fault.
what is the differencce inn series and cascade connection??
What is the comparison of PILC and XLPE cable
can i use the six sigma method which is used in management area, in state estimation of power systems?
in control scheme dc logic wiring commonly using negative loop,what is the reason?if we use positive looping what will happen?
List of equipments required foe industrial repair lab.