In the diesel generator if there is an AVR (auto voltage
regulator) gone faulty, in this condition is there any way
to generate the voltage from the alternator? I need a brief
explanation can you please help somebody
Answer Posted / sheikh
in any type of generators if AVR has become failed
then not possible to generate the voltage, because excitation
is comulsory to megnetized the alternator field winding
in case of AVR faliuer exitation also must be failed becaus
AVR is supplied the exitation volage either no load condition
or on load condition AVR also incrase and decrease the
exitation voltage and current as per demand of load.
Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
HOW TO CALCULATE THE REGULATION OF 100 AND 25 KVA TRANSFORMER
In India the supply voltage is 230 volt A.C. During the negative half cycle phase becomes neutral and neutral become phase? or what will happen during negative half cycle? how the electrons flow during positive and negative half cycle?
1.what is meaning of curve into a mcb. 2.what is basic reason changing of curve
give some advantages and disadvantages of combiniing the session, presentation, and application layer in the osi model into one single application layer in the internet model
What is dynamo?How it works and what is the function of dynamo in a DG.
What will be the fault current of any system when its generation is 10% of BASE generation( FUll Load )?Will is 10% or the same as full base calculation?
Why we do 2 types of earthing on transformer (ie:)body earthing & neutral earthing , what is function. I am going to install a oo kva transformer & 380 kva dg set what should the earthing value?
How we can calculate the consumption in kwh of motor on basis of kw @100% load, @50% load & @ no load.
can i use ups power as a raw power for another ups
Why a Permanent Magnet Generator has higher frequency as compared to frequency of main alternator?
which type of questions asking for solar companies?
how can i get the formula to find out the cable size if i know the load of main fuse protection.
As we use capacitior bank in 3ph ckt for improvement of PF, why not we use capacitor in single phase domestric use, at our house their are many inductive equipments,like fan,mixer,tube choke,air conditioner they also draw PF... by using capacitor can they improve PF. if yes--what are advantage and how to connect a capactor in single ph,and which type of capacitor if no- what are disadvantages.
Trafo ratio is 11kV/6.6kv,Vector group is YND11. What will be the effect if secondary is used for earthed system.
Salient pole alternator is more stable, why?