In a thermal power plant ID Fans running with full load but
boiler load is only 80 % give reason ?
Answer Posted / mohamed elnakib
it is due to the air preheater being clogged increasing the
load of the ID fans due to the bad suction and this clogging
is mostly due to the baskets being melted due to the
formation of the ACIDS from the exhaust gases and the dew
point effect .
this is the only logical reason for why the ID fan is 100%
loaded while the boiler is not .
| Is This Answer Correct ? | 12 Yes | 2 No |
Post New Answer View All Answers
What is difference between secondary Air & Tertiary Air and Their use.?
How We Calibrate the vaccum transmitter?
Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.
LAPT working in alternator / generator
How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.
explain how the third harmonic content of the magnetising current affects transformer design
what is restricted earth fault explain in details
what is the difference between compensated & normal drum level in boiler drum?
what is the trip circuit supervision in an electrical meaning?
operation
How to calculate power press toneage
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
what does mean by kva rating
What is LB-SR.
what's the moog valve