WHAT IS D/O D/I AND A/O A/I PLZ EXPLAIN

Answer Posted / raja

AI - analog input
AO - analog output
DI -digital ""
DO- digital ""

these are the input and output types used in external cards
inserted in a plc . this ensures a proper selection and
processing of signals by PLC .

Important point is that they may not be the direct output of
a field sensor but a modulated one .

e.g - thermistor is provided in a plc itself for temperature
measurement . then it will be connected in analog input card.
2. pressure control to a p to i converter will be connected
in analog output card .

Is This Answer Correct ?    0 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

1144


1. what is modbus cable? 2. what kind of communication we are using for the interface of DCS, ESD and Third party cabinets? 3. What is serial communication and peer to peer communication?

1677


How flow can be measured with dp?

673


how to calculate orifice sizing? and tell me if pipe size bet 50mm t0 200mm then we can use pipe flange??? and above 250mm pipe size should i use D & D/2 Flange? is it right or wrong?

1498


What is wet leg condition and why is it used?

1559






What is super thermocoupal?

1698


Explain the working principle of lvdt?

702


how to calculate control valve bonnet size?? or how to select its material?

1957


Hi,can anyone help me out with PhD programs related to Instrumentation field?I have a degree in electronic Instrumentation?

1480


How vortex sensor used for steam flow measurment can be checked on line i.e without taking out from process line.

1627


hii my name is sujith...i am preparing for HPVL GET 2010... so ,,,pls help me by send any previous questions or material to my site.....(Msujith_12@in.com) thank q

1462


What are the maximum packet size of: a) HART b) Profibus DP c)Profibus PA d) DeviceNet e) Foundation Fieldbus

5311


Explain the working of an enraf level gauge.

663


How to interfacing microcontroller with a DC motor

1251


How a conductivity sensor & analyzer work at boiler, whats the principle & science is beyond this,How conductivity sensor sence & convert signal & move toward analyzer & analyzer show reading in percent? also what is temperature compensate option in conductivity analyzer

2314