in case dc we mark as + ve & -ve..but in case a.c. we mark as
ph&N...Y LIKE PLZ TELL ME
Answer Posted / doss
actually there is both positive and negative voltage occurs in the phase(phase line) with respect to the neutral line. this speed of positive and negative voltage variation is purely depends on the frequency of the ac supply. that is during positive half cycle of ac supply the phase line is positive with respect to the netral line. and during the negative half cycle of ac supply the phase line is having a negative voltage with respect to the neutral line(i.e. neutral is positive voltage with respect to the phase line during negative half cycle of ac supply). so we cannot define positive and negative terminal in case of ac supply since the same terminal can act as positive in one half cycle and during other half cycle the same terminal act as negative. so we simply say it as phase and neutral.
Is This Answer Correct ? | 16 Yes | 1 No |
Post New Answer View All Answers
i karmveer bharti persuing b.tech . plz send me syllabus and name of reference books. for preparation of section eng.
why in an industry; machine having rated 200 h.p stopped after power factor is maintained above 0.97 lag by control panel in view-of energy saving
What is polar plot?
what is mind in cable
State how to produce a constant rotating field by application of alternating currents to stator armature of a three-phase squirrel-cage induction motor
A 230V dc shunt wound motor has an armature resistance of 0,15Ω.When operating on no load at 650 rev/min the armature current is 6A . The motor takes a full load current of 85A. Calculate the full load speed if the field flux is (i) maintained constant (ii)reduced by 0,03
What is an 86-P or an 86-A trip
dg started in plc mode and load taken later one battery terminal connection will be disconnected by loose connection what will happen for dg and shall we connect battery terminals while dg in load time?
why normally Generator rating are between 11Kv to 22Kv?
while doing high voltage test on 11kv/433 distribution transformer why we only give 28 kv on hv side and 3kv on lv side for power transformers what is the value what factors it depends
please send me the previous year's question papers of jindal GET exams
what is the difference between switchgear and circuit breakers and is there any difference between outdoor and indoor switchgear and circuit breakers , and how would you differentiate between switch yard and substation and grid station . thanks
Which device is used for the source of emission of electrons in a crt?
How to test IR testing & magnetic balance test
can u give me a brief idea about power line carrier communication ??