In 11KV Double pole structure for each phase we are using Disc one Insulator. Why we are not using 2 r above insulators instead of one insulator?

Answer Posted / kinslevel

The Disc is made in
such a way that each
Disc can withold 11kv.
So, you can only use 2
of the Disc if perhaps
you want to increase
the transmitting
voltage to about 22kv
or more.

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Application Comparison between 22KV (UE)and 33KV (E) system. Are we allowed to use 33KV (E) cable in lieu of 22KV (UE) cable. What are the technical disadvantages.

2295


What will happen if we introduce negative feedback to a control system that uses a positive feedback?

682


i need about 10 years of GATE solved papers in pdf format and even mock tests toooo

1209


I want formula to calculate current loss with distance in km.I searched many sites but didn't right answer.Plz reply me

1563


Can any body tell me the different types of LT cables & their application.

1635






Hello everyone, somebody knows what is a "surplice power" ? The hole phrase is: "This rating is appropriate for a generator set paralleled with an infinite bus e.g. a national electrical supply network or grid where the generator set is run at 100% load, 24 hours a day, 365 days a year and any surplice power is exported into the grid" Thanks in advance.

1265


When a single pase capacitor run motor- run on 230vac and Case(1)run with 8 Mfd 250 vac.capacitor , Case( 2) run with 8 Mfd 400vac capacitor. What is difference between both case regarding power ,efficiency etc?

1655


Can we test the alignment of End shield and stator of turbogenerator without rotor insertion? Also how to fix maintain the alignment at site installation?

1792


what clearance required for 4.5 mva dry type transformer?

1631


In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

360


Draw the circuit of clapp oscillator?

677


how we do Vector group ,magnetic balance and tap changer test in Transformer?

2035


please send privious years question papers of jindal steel and power ltd.My e mail id is rajanikant.sngh@gmail.com

1641


Let me know that how i calculate the alternator sub tranciant reactance and tranciant reactance.

2104


can any one suggest paper presentation topies for electrical engg?

1509