what is the difference between CPC and i/p converter

Answer Posted / bimalendu sarkar

the basic difference between them is that cpc has two
inputs- current( 20ma to 160ma) and a hydraulic
input/output whereas an i/p (E/p) converter has a current
(4ma - 20ma) and a pneumatic input/output.

Is This Answer Correct ?    7 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,

1667


Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer

4170


what is thermo coupler and how it works

4980


why we are using drum level control valve air to close?

1604


how works encoder in plc

1587






Sir , i have completed my M.Sc In Instrumentation and presently working in Maintenance department 3 yrs Exp , is there is any possible for work in offshore ..

1394


Describe the functions of the Operator Interface including the considerations related to alarming and display layout/configuration/layers.

1639


hello can yoy pls send me previous papers of jindalpower and steel ltd.....'m from instrumentation..... mani1048@gmail.com

1583


applications of plc in printing and packaging?

1674


what is insdustrial vibration.who it works. give atleast 2 types of insdustrial vibration

1563


can u plz send me technical questions asked in SCHNEIDER ELECTRICAL technical paper?

4282


How to find out the current of two motors having same power consumption but different RPM?

1539


why direct mounted pressure transmitters is always installed with DBB ( double bleed block) valve in process line or top of the tanks ?

1582


HOW TO CALCULATE ACCURACY OF AN INSTRUMENT. WHICH IS COMPITABLE FOR USE.

1810


Identification of ss fittings, pilot valves, relief valve.

1389