As an industrial instrument technician what we have to know?

Answer Posted / manoj cherthala

you must know basic instumentation such as parameters flow ,temparature,pressure ,level,and transiters,control valves ,control systems like DCS,PLC,SCADA etc

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Somebody tell me in what way i need to prepare for csio pgrpe(adv instrum eng)interview?what all the quest can i expect?

2114


Give Detail information about plc,dcs,and scada system?

1271


How to Calibrate Coriolis Flow transmitter in field

756


Instrumentation symbols interpration, P& ID, Logic diagram analysis, Electrical drawing analysis.

1496


what is your eligibility criteria for freashers?

1635






Can please tell mi about SIOS, PRM, SERVER, and what is the diference between PIN LAN, PCS LAN,APC Server, and please send the Doc if possible for referance,mail id patil_amit17@yahoo.com

1454


what are the values of fuel flow rate in various places in boiler.

1245


Why humidity limit is 30 to 55 % for raw material storage?

3622


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1452


what is actual drum level and compensated drum level?

1772


I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.

1365


How to calibrate H2s Dectector

1195


Explain the key components of control loop?

574


how to change measuring units from mmwc to cubm/h in rosemount air flow transmitter with hart communicator fluke 744

1927


Describe the function of Accumulator into the Pump

1486