Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

in how many ways we can make induction motor to run in
reverse direction?

Answer Posted / hemant

In 3 PHASE type of induction motor we need to change only a
phase sequence of incoming supply so its sequence of phase
angle get change(0,120,-120 electrical degree) is
responsible to change electrical field produce by phase
hence direction of induced emf get revers so and so its
rotor rotate in revers direction, in case of single phase
motor diection may change by changing capacitor terminale
which across to supply voltage.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1973


how to remover corona effect and hysteresis losses from contactor

2036


Maintenance of transformer???

2274


standard earthing rating for power line..

2138


how to test the turn ratio of 3 phase transformer using volt meter shoe the curcit diagram.

2464


What is the meaning of dedicated earthing?

2178


I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.

2281


How to calculate earth wire load by formula

2593


Good morning: I'm looking for some informations about the OLTC or the LTC: I wont to know what the function of the tie-resistor in during the operation of reversing/coarse operation Cordially

2015


Draw transformer phasor diagram.(full load,no load)

4190


What the main causes of transient interruptions on Over-Head Distribution Lines?

2159


Explain what cmos is and its benefits?

1104


Why 15Amp. MCB is suitable to carry load of 1.5Ton Ac please Explain?

2173


importance of reactive power management

2039


why induction motors are rated at 0.8 power factor.

2015