What is the reactive power and how to control the reactive
power in power plant

Answer Posted / r. parthiban

The partial portion of apparent power due to the stored energy (In Inductance) in the transmission line, return back to the source in each cycle is known as Reactive Power.
For Purely resistive loads Reactive Power is zero because sin0=0 and Active power only presents.
Whenever there is phase angle difference there will be a reactive power.
To Compensate this reactive power to get full active power, we use FACTS device (All the devices includes Capacitor) which is known as Reactive Power Control

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the magnetic field (coil DC ) of Turbo Expander?

1589


please send me the L&T Emb. sys. placement papers and entire details of pattren

1846


How can we choose the rating of submersible motors

2170


What is the formula to calculate the rating of a three phase air circuit breaker

1821


what would happen if reactive power (kvar)is increased (more)or decreased (less)? how much exact reactive power should be maintained? and what should be done for that

1779






How to determine the breaking capacity such as break down current and break down voltage for VCB and CT's.

1750


How can i calculate the Breaking capacity of molded case circuit breaker, is the breaking capacity of CB for Diesel generator shall be less than grid supply's breaker ?

1713


100 MVA 3-phase alternator with earthed neutral has a reactance of 5 ohms per phase. what will be the fault MVA of generator.

1845


Dear friends, i would like to know that what is the exact function of 'exciter winding' & 'aux winding' in Alternator?

1450


What is milivolt dop test in Busducts? What is its significance & procedure to do the test?

1587


How is the speed of a DC shunt motor related to the armature current?

680


a governer in an Ic engine controls the

706


Suppose a 3 phase, 2 pole, 440V induction motor is driving a flywheel of 600mm diameter, 150kg mass. By using v-belt and pulley, the speed is increased to 4500 RPM. What will be the effect on motor current?

944


why voltage form factor of PT are increase , when it is ecpected heigher spikes in system. how it is calculated.

1659


ITI r/tv trade APPLY (J.T.O VACANCEY) ALSO INCLUD AITT ELECTRONIC,WRITEEN XAM DONE 23.03.10 BUT NO RESPONCE WHY ANATHER ID gopal_gh007@rediffmail.com