Answer Posted / mohit kumar
in mmi switches or buttons are used so man operate it
mostly thats why it is called mmi
in hmi touch pannel is used which is operated by man or
woman thats why it is called hmi.....
Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
where are following valves are applicable to install. can any valve be installed any line. globe valve butterfly valve boll valve gate valve
where i can get training in INTOOLS and PDMS in Delhi-NCR OR north part of India. please reply with ur ans. at arunsamkaria@ymail.com
With N nodes and B branches what will have a network ???
what is the calibration procedure for transweigh make weigh feeder?
NPN transistor, SCR, Zener diode, LED, Varactor diode, Vortex meter, RTD, Resistor, Crystal
What is frequency factor in massflow meter? When using frequency output?
what is the difference between scaler and vector drive
(1) In turbine, what does term CDP, NI, NH, HSSOC, means. (2) What is the purpose of LO overhead tank in turbines.(3) An equipment is certified for EEX, IA, IIC,T6, what do you under stand by this.(4) what is SURGE, and how it is prevented, what is the purpose of bypass valve across AS valve.(5) Give 2 application of quartz crystal used for process parameter measurement.(6) what is meant by cold float of compressor shaft. (7) state four different types of flow measurement. For gas flow measurement mmscfd is the common unit. Expand the unit and specify significance of word S in the unit.(8) what is meant by Gap voltage, in vibration measurement. Normally how much Gap voltage is set and state the reason.(9) what will the new flow factor if D/P transmitter is Re-Ranged from 25” wc to 50” wc.(10) what is the usage of QDV & Volume booster.
Why mixer nd grinder Is example of constant torque load not variable torque load ???
how do u calibrate the vacuum transmitter if it shows more reading
how to measure oxygen which methods are using?
Tell about your IFFCO plant visit.
What is the GK Value in Flowmeter?
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
what is stroke check for field instument transmetter's & AOV's