Answer Posted / randzu
Is an automated electrical power isolator, which under
fault/heathy conditions, breaks or make circuit of the
protected load or equipment through the command of
relay "refered to as the brain of electrical protection".
The combination of Circuit Breaker, Protection/Metering
Relay, Current/Voltage Transformers and Fuses make a
switchgear. Circuit Breaker alone CANNOT be regarded as a
Switchgear, as all the above mensioned equipment work
antagonistically to bring about the end result of
electrical system
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How can ou verify the size of conductor 50Sq.mm ACSR
derive DC RMS value for half wave rectifier?
what is formula to cal cute earth pit numbers and size of earth strip used in earthing?
What is I to C?
how to design coil turns ?
why does the magnetic balance tests at transformer?
What Normal(Tangent) towers and Tension(Cut-point) Towers?
can anybody tell me that for p.f. Improvment we use capacitor banks but how to decide its capacitance. As we all know how to calculate kvar but what abt capacitance value
how can i determine the KVA/MVA rating of transformer precisely?? is there any standard test?????
sir,in our plant we r using SATEC PM172E power reading meeters in HT panel side it is monitoring the MB data smart viewer(sever).but last one week we did not get readings inthe server only available in meeter.tell me how communicate meter and server. and also what steps we take for checking.
What does quality factor depend on in resonance?
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
In EDO ACBs what is a purpose of closing coil and motor, what is the operation of these devices are they inetconnected. means if we give supply to motor and by BCS we charge Closing coil,what exact is operation is and how it charge a spring of ACB. Sir if anybody has an wiring diagram please send me the link to operate and EDO breaker.
H.t motor 6600 volt to same motor lt supply 440volt supply applyed to h.t motor to effect....
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes