why are set -10vdc in bently neveda vibration system.

Answer Posted / sudhansu

Bentil naveda vibration senser works on proximity principle of eady current type.so as the manufacturer define it as npn transister type so we got a negative proportional voltage with respect to gap generated.
so -ve output is due to -1)eady current and 2) for npn transistor.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1451


I need control valve ISA hand book. Is there any site to download that big book containing all the pages. Written by Paul Friedmann

1882


How many are the types of instrument cables in terms of No. of pair.

1706


What is megering????

13920


What is solenoid valve? Where it is used?

612






What is the difference bitween control net scaner and device net scaner

2954


how to turbine speed measurement?

1164


what is interface level and how it is calibrate?

1768


What is the Working principle of Dozing valve?

1778


Define the terms Accuracy, precission, Spam, process tolerance while doing calibration of an instrument? Explaini with an example?

1567


when the instrument tapping on pipe line is located below and transmitter is located above the tapping point for liquid service transmitter, what should we do, is there any additional drain valve is required??

1716


For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?

2654


What are the charcterstics of a P&ID controller block for Governor speed raise or lower for a load sharing functionality between 4 Gas turbines in droop mode.

2503


I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?

1773


What is mean by analytical instrumentation?

1281