what is the difference between SMART and tipical transmeter ?

Answer Posted / bhimrao mane

SMART MEANS SINGLE MODULE AUTORANGING TRANSMITTER AND THE
DIFF IS ORDINARY TRANSMITTER SHOUD NOT AUTORANGE MEANS IN 4-
20MA IT NECESSARY CALIBRATE WITH THIS VALU BUT IN SMATR
TRANSMITTER IT WILL AUTO RANGE IN 4-20MA.MEANS IT ATTUNATE
AND TUNE SELF WITH THIS VALU.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How process line mpm calculation is done?

851


Make Heater Process Logic.

1642


need instrumentation job completed 1 year trainee ship in mnc pesticide company. now in search of job

1483


what is metal of piston ring

1500


which type inter lock use in petrochemical refinery,and oil & gas?

2633






State bernoulli’s application.

673


What is mean by analytical instrumentation?

1281


What types of Instrumentation Related Questions can an Interviewer ask in a Telephonic Interview ?

2053


WHY THE DEGREE OF VALVE PLUG AND VALVE SEAT IS SLIGTLY DIFFERENT I CONTROL VALVE TRIM DESIGN

1548


we have a s-5 simense plc having op7 .recently on op7 showing error 1.plc not present 2. DB error frequently. can u have any solution . please send me.

2159


Hi my friends Is any one who can assist me in knowing the typical interview questions for system engineer at General Electric pty Ltd

1640


what is function of switch, and how is it work, explain with difination

1798


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1452


i have done DAE in Instrumentation and Process Control. i have applied for an apprentice training in chemical company after three day my interview will be conduct but i need more information about industrial process control and controller. my e mail is imran_dilsetu@yahoo.com please tell me interview question relative to instrumentation ?

1876


when the instrument tapping on pipe line is located below and transmitter is located above the tapping point for liquid service transmitter, what should we do, is there any additional drain valve is required??

1717