What is the use of keyphasor in turbine.
Answer Posted / raj
Keyphasor use foe turbine RPM measurement
Is This Answer Correct ? | 28 Yes | 30 No |
Post New Answer View All Answers
Explain types of valves?
How to change dcs card in online. (Dsc is maxdna)
where proximity sensor installed on tank in loading arm application
in valve is constructed as per SME B 16.34, then which standard is used for fire testing of valve?.
Instrumentation symbols interpration, P& ID, Logic diagram analysis, Electrical drawing analysis.
(1) In turbine, what does term CDP, NI, NH, HSSOC, means. (2) What is the purpose of LO overhead tank in turbines.(3) An equipment is certified for EEX, IA, IIC,T6, what do you under stand by this.(4) what is SURGE, and how it is prevented, what is the purpose of bypass valve across AS valve.(5) Give 2 application of quartz crystal used for process parameter measurement.(6) what is meant by cold float of compressor shaft. (7) state four different types of flow measurement. For gas flow measurement mmscfd is the common unit. Expand the unit and specify significance of word S in the unit.(8) what is meant by Gap voltage, in vibration measurement. Normally how much Gap voltage is set and state the reason.(9) what will the new flow factor if D/P transmitter is Re-Ranged from 25” wc to 50” wc.(10) what is the usage of QDV & Volume booster.
How can we use feedback signal frm rtd for monitoring and in dcs for controlling ,then which type of rtd is sutaible 2 , 3,4wire and why ?
Draw bode plot of any transfer function. Why is plotting bode necessary?
What care will you take in the installation of control valves,SCADA,DCS and FOC in Oil and Gas Project?
can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.
which type of filter gives the constant phase characteristics?
We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.
What is the purpose of bypass valve across AS valve.
Why not come out analog output in ABB EL3020 when display show correct value
what is the calibration procedure for magnetic flow meter @ onsite