The rotor current is directly proportional to slip. How?

Answer Posted / ashli

emf will be induced in a conductor only if there is a
relative motion b/w magnetic flux and the conductor.. when
ac supply is given to the armature of an induction motor a
rotating magnetic field is created(at synchronous
speed).now an emf is induced in the rotor winding and it
starts rotating. the direction of rotation is same as that
of rotating magnetic field but speed less than than syn
speed.. ie the relative speed b/w the rotor conductor n
rotating magnetic field is the difference b/w rotor speed
and syn speed ie slip. emf induced in the rotor and hence
the rotor current depends on the relative speed or slip.
that is how the rotor current becomes proportional to slip

Is This Answer Correct ?    6 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

clarify types of motor operated valves and advantages

1472


how is positive, negative, zero sequence is happen.. how is effect on 3 phase system

1294


for 4 MVA , 33K.V/6.6K.V transformer. secondary side the connected load is 3000H.P. What is the rating of capacitor bank to be insttaled.

2151


operation of protection relay watchdog contact?

1947


What are unstable systems?

658






How many size of cable required for a 300m long and 30kw inductive lode

911


sir iam from electrical and electronics branch ,can i appear for the hpcl offline requirtment? if yes please mail me on vikram_raju25@yahoo.co.in

1554


What is true sine wave or pure sine wave inverter?? Is it sine wave or step wave?? If it is step wave, waves with how much step is considered as pure sine wave? Is it possible to produce pure sinewave using power electronics?

1385


I want to calculate how much capacitor we connect to maintain the unity power factor? Is there any formula? Pls give me the answer

1452


HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.

1458


What is different between Difnit time and instatous over current relay

1985


What are the relays in ACB and VCB

1697


What is the purpose of using busbar mounting fuse?

1603


Hi everyone, I'm Lachuu, recently joined automation company as PLC Engineer. I have certain basic question, I request all big gurus and seniors to answer these question. Because this will be very helpful to me as well starters like me. How to design a control circuit (ex: pick & place - my current project) Yamaha robot PxYx series controller RCX222, using 6 cylinder double acting, plc keyence kv p16r 2 expansion unit for input and output each. How to select panel terminal mcb elcb powersupply. My main concern in some projects how to select dc power supply, mcb rcb(I came across dif bt b c d curves, but stil confusing, pls help me :-(. I would really appreciate all who are going respond to this question.

1510


How 3 phase invertor works?

1502