Question what"s the formula to find the quantity (consumption) of
cement,sand,aggregate for 1m3(1:2:4)?
 Question Asked In Companies :: ABB, L&T, Saudi Oger, Construction, l, Isher, Spectra, Strati,     < I also faced this Question! >
 Question Submitted By :: shaunpaulstar
  Answer Posted By  
 
Answer
Generally its easy to find it.

Find Total Parts = (1+2+4)=7 Parts.

For 1 cu.m of concrete the total parts = 1.57

Unit weight of cement = 1440 kgs

Cement = (1440/7)*1.57 = 322.97/50kgs = 6.46bags.

1 bag cement= 1.25cft

Sand = 6.46*1.25 = 8.075 cft*2 =16.15 cft

Aggregate = 8.075 cft*4 =32.3 cft.

Thats all...

Result:
Cement = 6.46 bags
Sand = 16.15 cft
Aggregate = 32.3 cft.


Regards,

Er.Vigneshwaran S

Is This Answer Correct ?    4 Yes 9 No


 
  vigneshwaran s
 
View All Answers
 
 
Please Help Members By Posting Answers For Below Questions
 
 Question Views   Select
 
if dia of inner circle is 42 m and depth is 1.5 m and width is 1 m ,then whait is the quantity of steel? 834
How to calculate the quantity of materials for M20 grade concrete 334
How to plan a project 433
I want to calculate the footing 90º L bend as a techincaly 438
please send me bhel questions on rupesh.017@rediffmail.com 897
What are the alternate material for steel, Sand and aggregate 402
How to calculate the force on a column of three story building. What should be the base concrete height?. 353
Any strength is a stress but any stress is not strength 89
Please tell me vasthu room sizes. Thanks. 516
residential projects,structural. 1071
What should be the lap length in raft if height of raft is 0.800mm ...it couldn't b 50D or 40D...we just have to join upper and bottom reinforced...is there any formula for determine it... 8
Which is the indian standard code of line out. ? How much tolerance fot 1 mt lenght? Its challenge.... 404
What is the difference between pvc,cpvc and upvc and where it is used as per their properties????? 895
In a beam,stirrups are placed closely at ends than at centre due to shear.similarly where would ties be closer to each other-at center or at ends in a column and slab. 1558
Why should you show Client/Engineer activities clearly on the project plan? 397
E-Mail New Answers        Answer Selected Questions