MY QUATION IS ABT THE MAIN POWER TRANSFORMER IN STEEL
PLANT , I WISH TO KNOW THAT WHY TRANSFORMER PROTECTION NOT
TRIP AS CABLES ON THE SECONDAY SIDE IS WATER COOLED.
TRANFORMER DETAIL
NORMAL KVA--150 KVA
PRIMARY VOLTAGE --34.5 KV
SEC.NO-LOAD VOLTAGE---1.290-908-690V ( WITH PRIMARY DELTA
CONNECTED)
CONNECTION--D/d (EXTERNAL CLOSED)
CONSTANT RATEING FROM--1.290-908V
CONSTANT CURRENT FROM--908-690
VECTOR GROUP--D III
Answer Posted / k.prakashchandra
As pure water is a bad conductor of electricity
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
how to calculate cooling requirement of datacentre from electrical load?
What are the parts in a inverter?
i want use the cable size 16cx4 core aluminium usege watts 240x2000w this cable size is correct?
How RTCC panel is working and give single line diagram for RTCC with transformer?
if we apply 1000ADC instead of 100ADC or We apply 50ADC instead of 100ADC,What will be happened in the test result value.Pl explain
at work i have a genertor/alternater what is the easyest way to work out if it is dc or ac?
What will be the fault current of any system when its generation is 10% of BASE generation( FUll Load )?Will is 10% or the same as full base calculation?
What will be the output voltage of a transformer if it is primarily energized from a square wave voltage source?
What are the various kind of cables used for transmission?
what are the advantages disadvantages of connecting high voltage block( 1:1 transformers) transformers between the turbo generators and busbars.
I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.
Different STANDARDS (BS, IS, IEC etc) gives different informations on CT specification. How they correspons w r t each other (i.e I mean to say BS provides "knee point voltage" but IS does not, then how can i select CT)
my name is venkat .i have good percentage in my academics(ssc 86, intermediate 83 b.tech 73) my question 1..after completion of my ssc i joined in bpc but i didnt got rank in emcet so i completed MPC in one year compartmentally ..so here what am expect question from this background?
what is the practical application of full adder circuit?
WHY THE COLOR OF OUTDOOR TRANSFORMER IS BLUE ONLY???