T4 temperature is the point where the temperature is
measured in the turbine at 4th position.
1. Ambient temperature (Outside enclosure)
2. Gas generator inlet temperature
3. GG air outlet temp (Where P2 measures)
4. HP to LP (PT) turbine temp (After fired)
This is used to measure the temp of hot gas passes out from
the HP turbine, which has left side 4 probes & right side 4
probes.
It trips the compressor (Turbine) when there is 120deg c
difference between left & right avg.
It trips comp when avg temp goes more than 740 deg c (due
to air-fuel ratio).
These informations are partically observed from MAN TURBO
THM 1304 gas turbine.
Is This Answer Correct ? | 3 Yes | 3 No |
Post New Answer View All Answers
Why rdt and thermocouple both give different output .and one things more, how to generate ohm or mili volt plz mail me merajalam143545@yahoo.com
What are different types of valves?
flow transmeter accuracy 0.075% of full scale & find ucertainty is 0.025 % so what is maximum limit band of uncertainty
what is commisioning procedure,2)what is is the main work in commisioning in the field tx to dcs, plz send me detail
I faced several time siemens ps2 positioner automatically getting Chang in it's set point direction after auto calibration So is there any causes biside this or any permissives ?
In Safe Guarding test what means by "Failed to Danger" ?
how to design orifice plate?what is the equation?
What is Alpha & Beta fctors related to Orifice Plate & its relation with flow?
What is hp & mp seperator .& what is its working principle ?
Actual using of tube bender to bend 2 opposite 90 deg at correct measurement center to center of tubing.
what is IEC code in cables & how to selecting cables?
What is the working principle of the magnetic meter?
Explain working principle of lvdt?
Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .
How to calibrate Toxic gas detector?