In ac circuit R,L,C are connected in series what is the output
the circuit? explain
Answer Posted / arun
constant voltage and constant current
Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
What is the rate of WCT on the Electrical Contracts comprising of DG Sets and Civil Works in Delhi ?
How to select a transformer group to connect a 0,433 KV generation with 33 KV grid in bi directional flow of current
What is the formula to find out two phase active & reactive power
ow can i get certificate of competency as electrical supervisor and my diploma in electrical engineering from jalgaon.
In synchronous motor, how the field current is related to armature current..i know its inversely proportional..but concept wise...i was nt clear....pls help me...
how to calculate micom relay earth falt time and current sertting
What is the tension required for the 25000 CFM AHU belt
In constant power region of 3-phase IM torque-speed characteristics, if frequency increases flux A does not alter B decreases C increases D none of above
As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?
WHAT IS THE DIFFERENCE BETWEEN AN ACB & mccb 7 WHAT IS THE CRITERIA WHEN TO USE WHICH OF THE TWO
i am going to attaned the engineer (disign)iterview at HAL please give me duid line
for compensate 315mh inductance ,how many capaciance required?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
what is the difference between directional & non directional earth fault with example please explain.