there is a power transformer 66/11kV in delta-delta
connection has 5 feeder coming out from the secondary side.
One of the feeder in it normally loaded (loaded than other
feeder)and this feeder usually trips with double OCR causing
the bank transformer to trip. Now if the load of this feeder
is put on other transformer then that no problems occurs on
that transformer or the load. However normally all the
test(IR, PI, short ckt, open ckt,grounding test and other )
has been conducted for this but evertything transformer.....
I am not geting what is the actual problem...

Answer Posted / k.prakashchandra

More data is required for analysis.If the transformers are
of same capacity and relays are identical ,interchange the
relays of transformer banks and watch.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have a situation to design sub-Distribution board/Panel meant for feeding power sockets. In the incomer CAN i Take TP MCCB with Neutral Link and All the outgoing feeders with to sockets with TP MCCB and Neutral Link? P.S : My System is IT Earthing

1310


I want the details about BHEL company examination.Can anyone able to help me please.

1592


Comparision of Air break circuit breaker, SF6 Circuit breaker and vacuum circuit breaker.

1927


i am in need of AC SYNCHRONUS MOTOR 30KW. ANY ONE KNOWS THE MANUFACTURER OF SAME. ALSO MOSFET AC CONVERTER 20KVA CONT.OUTPUT.

1458


Why induction motor is widely used in industry

2261






Earth leakage relay basic knowledge principle

1734


How we calculate DC inducation moter Amp? Sir pls give me formula......

1425


In India the supply voltage is 230 volt A.C. During the negative half cycle phase becomes neutral and neutral become phase? or what will happen during negative half cycle? how the electrons flow during positive and negative half cycle?

1490


hi, could someone help me to find a control design for syncronising panel .

1266


why sielent pole is used only in hydro generators and not in turbo generators

3352


When are the directional relays used?

606


What is dc current source? Differentiate between ideal and non ideal current sources?

802


How to decide and select the different earthing wire size for the different types of earthing

1807


How to do bus bar short circuit calculation for 230KV/11kv, 60 MVA Substation?

4258


1.why we are using metal oxide gapless block in lightning arrester,2.What is minimum and maximum rating of metal oxide blocks using in india

1512