What is difference between dc three point starter and dc four point starter?

Answer Posted / boo123pavani

In three point starter NVR (no voltage relay)is series with
Shunt if voltage falls certain value NVR De energized due to
insufficient magnetic field and motor turned off. But in
four point starter NVR energized directly from DC supply
thus the draw back of 3 point starter rectified


A motor can be run for a higher speed than normal speed by reducing the field current. reduced the field current may not produce enough magnetic force to hold the handle in on position. so handle returns to off position. this is the disadvantage of three point starter.this is the advantage of four point starter. it will not returns to off position

Is This Answer Correct ?    5 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the application of Dyn1 and Dyn11 vector group of transformer?

2433


what is the grounding Calculation formula? spouse i want to provide grounding to 3phase 18kw motor or i want to provide ground to 3phase 10kva dry type transformere or you give me any exemple...... Thanks.

1464


Percentage losses in power generation?

2495


why ups rating in kva? and why ups are in parellel?.why isolation transformer is used in ups?

1473


What are the functions of different probes used in cro?

678






ht side line to earth voltage

1075


why Lightening Arrester Probe sharp at Top of telecom tower.

1098


Can Anyone Answer anyone of these ? Q1) why direct SOLUTION of Load Flow Studies in Not Possile ? Q2)Why majority of Buses in power system are load buses Q3)Why one of the buses in Power system is taken as reference bus (slack or swing) Bus ? Q4)Bus Admittance Matrix is a sparce (means it contains some zero elements ) matrix , give reason

1358


who invented active elements? plz give me the complte details of active elements...

1419


which fault is severe and why?between lll fault and lllg fault which fault is severe and y?

2004


What is resistance reading of earth copper rod with grid and without grid?

657


Draw a block diagramof Three UPS systems connected in Parallel mode?

1673


why in an industry; machine having rated 200 h.p stopped after power factor is maintained above 0.97 lag by control panel in view-of energy saving

1593


what is the interrelation between voltage current torgue speed and magnetic flux in case of different types of electric motors

1531


What is the meaning of floating point earthing in battery backed systems ?

1483