What is the difference between PLC and DCS?
Answer Posted / eid elatawy
PLC is a programmable logic controller which take the inputs from the system and execute it through the program written by Ladder or STL (statement list)language and provide the output to the system.the famous CO Siemens,Allen Bradly.
DCS is distributed control system the same idea for PLC for take the input and execute it through the program to provide the output.the famous CO Yokogawa,Honeywell
We can enumerate the difference as following:-
PLC
1- no of points less.and almost of these points digital points.
2- no of analog points very less.
3- trends and history not allowed.
4- used for machines and separate units with HMI and in this case called SCADA system.
5- cost is less and easy to make extension.
6-scanning time less.
DCS
1- you can use more than 10000 points
2- no of analog points more.
3- trends and history allowed and saved in server for along time.
4- used for a big plants like oil&gas-chemicals and petrochemicals..
5-cost very high and you have to min cost of the system + no of points separate. so the extension not easy like PLC
6- Scanning time more than PLC.
7- We can monitor the all inputs and control all outputs
Regards
Eid Elatawy
I&C Engineer
TCI sanmar chemicals CO
Port said
Egypt
contact no- 002 01000470262
mail- eng.eid72@gmail.com
| Is This Answer Correct ? | 3 Yes | 2 No |
Post New Answer View All Answers
What are the types of control valves available
in which principle pressure tx,level tx ,flow tx,temp tx ,control valve works?
give eg of how I/P is used in control loops
How addressable fire systems work? Pl. send details with architect.(Loop), also send details regarding Gas system. Pl. help me.Thanks
defination of radial vibration?
what are the different types of Protocols? & their applications.
the pump holds on run indication into the dcs and filed local control panel remote push button condition operaton wrong like when the push button pushing conditions the pump is off and the push button release condition the pump is on totally opposite condition . And control room inside give the stop command into dcs just 1secon relay engage and again normal condition. How can I slove
what is 24vdc live and dry supply
we have a s-5 simense plc having op7 .recently on op7 showing error 1.plc not present 2. DB error frequently. can u have any solution . please send me.
CONTROL VALVE OPERATING IN MANUAL BUT NOT IN MANUAL. WHAT SHOULD BE THE PROBLEM ?
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
what can of fault ofently come in vibration mesurement?
what is the reason while warning lamp is on while the engine is cranking?
Can anybody tell me which type of question are asked in the interview for the FORMULATION(Pharma) as a instrumentation engineer, & question in building managment system.
How to convert mmWc(mili meter water colam) to tph(ton per hour)?