what is difference b/w HT & LT and the range of HT & LT ?

Answer Posted / hardik patel

nothing more diff but, as per voltage level we divide the
voltage level in diff-diff part.
LV-LOW VOLTAGE-UP TO 750V
MV-MIDIUM VOLTAGE-750-3.3KV
HV-HIGH VOLTAGE-3.3 TO 33KV
EHV-EXTRA HIGH VOLTAGE-MORE THEN 33 KV

Is This Answer Correct ?    0 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why do we avoid electrical conduits in floors at apartments?

1627


If I bring a basic electric meter from the States and hook it up in Costa Rica in a development that has only one transformer for the 50 homes, will it still be accurate regarding the usage of kilowatt hours?

1500


i need to now what will be the cable size to the following load, transformer to distribution panel distance 110m, load 1000kw, voltage 400v, pf 0.85, permissible voltage drop 2.0%, overhead line, atmospheric temperature 35 degree c.

1191


DG Earth Value?

1871


for a 400kv t/m line with 10 ampere current will corona occur?

1713






what is the size of ht cable of 33kv ht line and transformers ratings are 1 Mva and 5mva.please send formula also.

1007


delta motor winding resistance I take normally single winding is 2.5, which value is came delta connection ie RY ?

1546


is it possible to say motor horsepower number without seeing name plate(when name plate damaged)

1592


upto how much low RPM we will run the commercial motor which is run through VFD without any problem occurs in motor.Motor rating Duty is S1 & RPM is 1400.

1640


why Lightning arrestor are made by 2 seperate stack of inslutor but why cvt are in single stack of insulator.

1525


what is a bus post insulator? explain its application in a substation.

11745


What si the d/f b/w KVA & KWH, kvarh & kvar, kwh & kvar phase voltage & line voltage

5594


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

975


What are the basic properties of signal flow graph?

694


What is the ratio of Booster transformer?

1656