Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the need of ISOLATION Transformer?

Answer Posted / lakshmi

isolation transformer is a 1:1 transformer. its basic
principle is same as that of ordinary transformer. only the
difference is it can`t step up or step down the voltage. it
provides only isolation between primary and secondary.
strikly speaking that isolation transformer provides more
safety for electrically operated equipment like hand
drilling machines, electric shaving kit etc.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to design a Unit auxiliary transformer for a power house having a unit of 65 MW and Generating voltage of 11 KV and Secondary voltage of 433V

2137


Describe the test procedure to determine the vector group

2161


The power factor of the fixed load is 0.8, now the p.f is varying from 0.8 to 0.5.

1989


why zero sequence impedance measurement is not applicable for single phase GT

2205


what will be project cost for 100 kv transformer connection under oyt scheme.

2939


dear all i am kumara now current working in electrical designing of control and relay panel i want learn some substaion design then any book are available. pls mention name and authour

1959


electrical knowelge

1179


In Generator How suction compression power and exhaust works ?

1951


Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir

1942


how to calculate single phase motor efficiency ?

2214


HAI SENT HPCL APTITUDE QUESTION PAPER, MY EMAIL ID IS angus_eee04@rediffmail.com,angus_eee04@yahoo.com

2266


why wire sizes are 3/29 or 7/29 and why not wire sizes are 2/29 or 6/29?

5154


define as synchronous generator

2154


How to calulate Locked rotor amper(LRA) for compressor type motors?

1784


why genarator genarating voltage 11 KV?

1793